Eg4 inverter12/18/2023 ![]() ![]() Please comment again, I want my setup to be correct. I think someone commented on this setup that their maybe an issue I haven’t just covered in my reply. Also the bus bars are from amazon, however they said they could take up to 250 amps I have not stress tested this system without my upgraded battery cables. ![]() I made the battery rack out of unistrut and heavy unistrut brackets. The back board is just tongue and groove pine. lol, it’s only temporary) The main conductors go into a junction box and conduit to the batteries just to keep it cleaner so heavy wires sent on the ground, I have kids and babies. The battery cable is 4/0 underground cable that I cut open and removed individual strands ( and yes at the battery it’s connected to 6 awg. ![]() This current setup was to insure everything worked correctly, however I can still pull a decent load with this thin cable between the batteries. The battery cables are what came with the batteries and yes they are small, they have to be made bigger. Trying to reply to all the messages I missed. Lastly - if both of these inverters get setup to run in the split phase configuration, can I only run a single string of solar amps) to only one inverter to charge the batteries? Or do I have to balance solar inputs between inverters? What’s going on? I would like to run these split phase to run my well. 2P2 doesn’t display its setting on the LCD screen in the top left hand corner. Also with 2P1, it displays 2P1 in the top left hand corner along with the battery icon in the center. EG4 Inverter Installation Full System Wiring And Tips Off Grid Solar OUR SOLAR EQUIPMENT.CLICK HERE. Since 2P1 only shows battery icon it auto shuts down within about 20 seconds. Upon restart, both inverters turned on, 2P1 only shows the battery icon, 2P2 shows the battery icon, A/C to D/C icon and Power output icon. Set First inverter to 3P1 (3 Phase, unit 1) Set second inverter to 3P2 (3 Phase unit 2) Set third inverter to 3P3 (3 Phase Unit 3) Split Phase (180o phase shift) Use this with 2 inverters for Split Phase 120/240 power. After this setting had been made, I shut down both inverters and performed a restart. Use this with 3 inverters to produce 3 phase power. Second - When placing both inverters to the split phase connection, I identified one as 2P1 and the other as 2P2. I really don’t care for all the communication cables, can I run without them and allow the inverter to know battery status just by old school voltage? The only way to stop the alarm was to select battery type as user and input my own battery voltage settings. All comm cable connections were hooked up per manual. I was wanting to run this system in split phase configuration, but I discovered some issues along the way.įirst - When making the battery selection in the inverter menu #5 I could not choose the EG4 battery setting because a fault #61 would constantly flash saying comm loss with the battery. The 6000XP is now available for purchase at EG4's trusted distributors.įor more information about the 6000XP and its specifications, please visit. ![]() With integrated disconnect, the 6000XP is designed for optimal performance. This feature allows for 120/240V service application with only a single unit, simplifying the setup and reducing costs. The 6000XP is designed to communicate seamlessly with EG4® 48V batteries and other battery brands, offering flexibility and compatibility. The mountable Wi-Fi device facilitates wireless communication between the inverter and the new EG4® monitoring platform through a user-friendly app or online website, enhancing control, monitoring, and firmware update capabilities. It supports the utilization of up to 8000W of PV input, eliminating the need for a combiner box. With a maximum input of 480VDC, the 6000XP allows the use of smaller wire sizing for its 2 Maximum Power Point Trackers (MPPTs). The 6000XP is an all-in-one solution, capable of running entirely off-grid or with grid input for supplemental charging and power output. With its cutting-edge features and unmatched efficiency, the 6000XP empowers homeowners to harness the full potential of solar energy while ensuring a reliable, sustainable power supply. Sulphur Springs, Texas, Date – EG4 Electronics®, a pioneer in renewable energy solutions, proudly announces the launch of the EG4® 6000XP, an innovative 48V split-phase off-grid inverter/charger designed to revolutionize solar power utilization. EG4® Unveils the EG4® 6000XP: A Groundbreaking Off-Grid Inverter/Charger Redefining Solar Power Independence ![]()
0 Comments
Read More
Leave a Reply. |